Electrode Specifications

Source-supported electrode parameters

11 specifications, each mapped to a discrete fact from our published test data: HER and OER overpotentials, the electroless deposition process, the Ni foam substrate, the 5 cm² AEM test cell, and the dynamic-load and 1000-hour stability runs.

Key parameters at a glance

All values as-measured, without IR correction where applicable.

HER overpotential80 mV@ 100 mA/cm², no IR
OER overpotential260 mV@ 100 mA/cm², no IR
BifunctionalYesSame electrode HER + OER
Cell @ 0.5 A/cm², RT1.81 V82% energy efficiency
Cell @ 0.5 A/cm², 60 °C1.62 V91.4% energy efficiency
Cell @ 1.0 A/cm², 60 °C1.79 VIndustrial current density
SubstrateNi foam100 to 1000 cm²
CatalystBi-metallic NiCoElectroless-deposited
Electrolyte30 wt% KOHZero-gap AEM cell
1000-hour drift21 µV/hr@ 0.5 A/cm², 40 °C
ΔV before/after 1000 hr30 mV@ 0.5 A/cm²
100-hour wind cycling ΔV20 mV@ 0.5 A/cm² before/after

All specifications

PerformanceOverpotentials and cell-level operating points
Architecture & MaterialsWhat the electrode is made of
Test CellHow the published numbers were measured
Stability & DurabilityLong-term and dynamic-load behavior